On/off Grid Solar Air Conditioner_Shanghai Sealey Air Conditioning Co., Ltd.


Current Position: Home >> Solar Air Conditioner

On/off Grid Solar Air Conditioner

    On/off grid solar air conditioner works perfectly under AC only, DC only or AC+DC, high SEER, wide voltage design, freely use different PV panel configuration according to your installation space, works perfectly under normal and T3 tropical climate. It equipped with MPPT PV tracking system, utilize the PV DC power as priority. DC directly power the indoor&outdoor fan motors and compressor. When the DC power is not sufficient, the AC power helps, thus achieve continuously power supply. This solution is perfect for the places where the grid power is not steady or grid power often cut.



    Specification of on/off grid solar air conditioner

    Model KFR-26GW/BPBLA KFR-35GW/BPBLA KFR-50GW/BPBLA KFR-70GW/BPBLA
    AC Power supply V -Ph-Hz 220~240V -1Ph - 50/60Hz
    DC Power supply V DC48
    Cooling Capacity       Btu/h 9000 (3500-11000) 12000 (3700-14000) 18000 (6200~19500) 24000 (9100-26900)
    Input power W 485 (100-750) 658(110-1200) 905 (140~1500) 1325 (240-1850)
    Rated current A 10.11 (2.08-15.63) 13.7 (2.29-25) 18.85 (2.91-31.25) 27.6 (5-38.54)
    Heating  Capacity       Btu/h 9500(3800-11500) 13000(4000-15000) 19000(4700~20000) 25000 (5500-30000)
    Input power W 505 (120-800) 675 (130-1220) 915(200~1600) 1345 (260-1950)
    Rated current A 10.52 (2.5-16.67) 14.06 (2.71-25.42) 19.06 (4.17-33.33) 28.02 (5.42-40.63)
    Indoor air flow (Hi/Mi/Lo) m³/h 570/470/370 570/470/370 721/566/458 970/780/590
    Indoor noise level (Hi/Mi/Lo/Si) dB(A) 41/36/28/23 41/36/28/23 44/39/35/25 45/39/34/27
    Indoor unit Dimension (W*D*H) mm 805x194x285 805x194x285 957x213x302  1040×220×327
    Packing (W*D*H) mm 870x270x360 870x270x360 1035x295x380 1120x310 x405
    Net/Gross weight   Kg 7.2/9.6 7.2/9.6 9.5/12.5 11.9/15.2
    Outdoor air flow m³/h 1500 1600 2100 2600
    Outdoor noise level dB(A) <48 <50 <52 ≤56
    Outdoor unit Dimension (W*D*H) mm 835x320x540 835x320x540 835x320x540 910x340x700
    Packing (W*D*H) mm 900x400x600 900x400x600 900x400x600 1063x480x760
    Net/Gross weight   Kg 33/39 35/40 39/44 56/62
    Operation temperature 17~31  17~31  17~31  17~31 
    Ambient temperature (cooling/heating) 18~52/-15~34 18~52/-15~34 18~52/-15~34 18~52/-15~34
    Application area 12-18 16-23 24-35 32-47